HPTLC Applicator Specification

  • Spare Parts
  • Spare syringes, power adapter, and stage holders.
  • Features
  • Automated programmable application, high reproducibility, user-friendly interface, multiple sample tracks, solvent-resistant construction, and compatible with all HPTLC plates.
  • Focus System
  • Not applicable.
  • View Head
  • Not applicable.
  • Theory
  • Automated application of samples in bands or spots on TLC/HPTLC plates for qualitative and quantitative analysis.
  • Drawtube
  • Micro-Liter Syringe with precision attachment mount.
  • Sensor
  • Precision XYZ programmable movement system.
  • Resolution
  • Spot positioning accuracy ± 0.1 mm.
  • Interface
  • Touch screen control panel and USB interface for PC connectivity.
  • Frame Rate
  • Not applicable.
  • Focal Distance
  • Not applicable (sample applicator, not optical device).
  • Magnification
  • Not applicable.
  • Dimensions
  • Approx. 450 x 320 x 250 mm.
  • Focus Range
  • Not applicable.
  • Eyepieces
  • Not applicable.
  • Eyepiece Tube
  • Not applicable.
  • Illumination
  • Integrated plate illumination for sample visibility.
  • Coarse Adjustment Range
  • Not applicable.
  • Fine Adjustment Range
  • Not applicable.
  • Working Stage
  • Adjustable plate stage to accommodate plate sizes up to 20 x 20 cm.
  • Still Image Capture Resolution
  • Not applicable.
  • Video Capture Resolution
  • Not applicable.
  • Image Format
  • Not applicable.
  • Interpupillary Distance
  • Not applicable.
  • Objective Achromatic
  • Not applicable.
  • Condenser
  • Not applicable.
  • Light Source
  • High-intensity LED plate illumination.
  • Software Support
  • Compatible with HPTLC software for data management and track programming.
  • Power Supply
  • 220 V / 50 Hz (standard); 110 V on request.
  • Number of Tracks
  • Up to 12 tracks per plate application in a single run.
  • Sample Application Volume Range
  • 10 nL to 1 mL (programmable volume control).
  • Material & Build Quality
  • Corrosion-resistant powder-coated metal housing.
  • Programming Modes
  • Single and multiple sample application modes with adjustable band length and width.
  • Safety Features
  • Auto stop on error, overload protection, and power surge safeguard.
  • Repeatability
  • CV < 2% for band area and intensity.
  • Operational Temperature Range
  • +10C to +40C.
  • Weight
  • Approx. 13 kg.
 
 

HPTLC Applicator About

HPTLC Applicator is highly acknowledged in the market for their high performance and durable in nature. The samples were applied in forms of bands on an aluminum TLC plate pre-coated with silica gel and were separated using dichloromethane: methanol: toluene: ammonia solution as the mobile phase. Further, this applicator are developed and validated for determination of sunitibin malate and possible impurities. Apart from this, HPTLC Applicator is simple in design, inexpensive to construct and ideal for applying small volumes of solutions to TLC strips and plates is described.



Precision and Repeatability for Reliable Analysis

Engineered for automated bandwidth or spot application, the HPTLC Applicator guarantees precise and consistent results with a coefficient of variation under 2% for both band area and intensity. Its micro-liter syringe and programmable movement system ensure accurate sample positioning and optimal reproducibility in both qualitative and quantitative thin-layer chromatography processes.


Versatile and User-Friendly Operation

This applicator supports single and multiple sample application modes, letting users adjust band length and width according to experimental needs. Easy operation is enabled by a touchscreen panel and intuitive software interface, while solvent-resistant construction ensures lasting durability. Integrated safety features, such as overload protection and auto-stop, enhance operational reliability.


Seamless Integration and Data Management

With USB connectivity and HPTLC software compatibility, managing your sample data and customizing track programming has never been simpler. The system accommodates up to 12 tracks per run and offers comprehensive plate illumination and an adjustable stage to fit various plate sizes, making it ideal for professionals seeking efficient, high-throughput chromatography workflows.

FAQs of HPTLC Applicator:


Q: How does the HPTLC Applicator ensure precise and reproducible sample application?

A: The HPTLC Applicator features a micro-liter syringe and programmable XYZ movement system, delivering precise positioning (0.1 mm accuracy) and automated, repeatable sample application with less than 2% variation in band area and intensity. This design ensures robust reproducibility for both qualitative and quantitative analyses.

Q: What sample volumes and plate configurations can this applicator handle?

A: The applicator accommodates a wide range of sample volumes, from as low as 10 nL up to 1 mL, all programmable for application. It can prepare up to 12 tracks per plate in a single run and supports TLC/HPTLC plates up to 20 x 20 cm, providing great flexibility for diverse laboratory needs.

Q: When should I use single versus multiple sample application modes?

A: Single application mode is ideal for precise, isolated sample placements or calibration runs, while multiple application mode enables efficient, parallel processing of up to 12 samples per plateperfect for high-throughput analysis, comparative studies, or routine quality control workflows.

Q: Where can this applicator be installed and what power supply does it require?

A: It can be set up in laboratories meeting an operational temperature range of +10C to +40C. The device requires a standard 220 V / 50 Hz power supply, with an optional 110 V variant available upon request.

Q: What is the process for programming and controlling sample application?

A: Users access the intuitive touchscreen control panel or use the USB interface connected to HPTLC software. Through these, you can set sample volumes, define track positions (length and width), and program either single or multiple runs, streamlining the entire sample application process.

Q: How does the applicator benefit laboratory workflows?

A: By automating sample application, the device significantly increases throughput and ensures uniform application, which minimizes experimental variability and maximizes accuracy. Its user-friendly operation and integrated safety features further enhance productivity and instrument protection.

Q: What safety and maintenance features are included?

A: The applicator is equipped with automatic error stop, overload protection, and power surge safeguard to ensure operator safety and equipment longevity. Routine maintenance is simplified with easily replaceable spare syringes, power adapters, and stage holders available from authorized distributors and suppliers in India.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Analytical Instruments Category

Over Pressured Layer Chromatography (OPLC)

Over Pressured Layer Chromatography (OPLC)

Fine Adjustment Range : Not applicable.

Light Source : External UV or white light source as per detection requirement.

Condenser : Not applicable.

Video Capture Resolution : Depends on external imaging system.

Frame Rate : Not applicable.

Interface : Manual controls, with connections for pumps and detector output.

Metallurgical Microscope

Metallurgical Microscope

Fine Adjustment Range : 0.002mm graduation

Light Source : 6V/20W halogen, reflected illumination, variable intensity

Condenser : Reflected light bright field condenser (N.A. 0.9 with iris diaphragm)

Video Capture Resolution : 1080p Full HD (with suitable camera, optional)

Frame Rate : 30fps (with compatible digital camera, optional)

Interface : Camera port (Cmount adapter supported), USB (with compatible camera attachment)

Inductively Coupled Plasma Spectrometer

Inductively Coupled Plasma Spectrometer

Fine Adjustment Range : Programmable via software for optimal alignment

Light Source : Argon Plasma torch, RF powered

Condenser : Echelle grating with cross dispersion for high resolving power

Video Capture Resolution : Realtime spectrum acquisition, 30 fps

Frame Rate : Up to 30 spectra/sec data acquisition

Interface : USB 2.0, RS232, Ethernet compatible connectivity options

Digital Genius XRF Analyzer

Digital Genius XRF Analyzer

Fine Adjustment Range : Not available

Light Source : Not available

Condenser : Not available

Video Capture Resolution : Not available

Frame Rate : Not available

Interface : Not available