WhatsApp Chat with us
Back to top
Automated Liquid Autosampler
Automated Liquid Autosampler

Automated Liquid Autosampler

Automated Liquid Autosampler Specification

  • Features
  • Programmable sampling sequences, cleaning cycles, leak detection, and error alarms.
  • Spare Parts
  • Sample probe, vials, tray, and replacement tubing.
  • View Head
  • Not applicable.
  • Focus System
  • Automated vertical movement for sample probe.
  • Theory
  • Fully automated liquid autosampling for accurate, repeatable sample introduction in analytical instruments.
  • Drawtube
  • Adjustable drawtube mechanism for precise sample volume extraction.
  • Sensor
  • Integrated liquid level and presence sensors for accurate sample handling.
  • Resolution
  • 0.1 L volumetric resolution.
  • Interface
  • USB 2.0, RS232, and Ethernet connectivity for instrument communication.
  • Frame Rate
  • Not applicable.
  • Focal Distance
  • Not applicable.
  • Magnification
  • Not applicable.
  • Dimensions
  • Approx. 45 x 35 x 40 cm (L x W x H).
  • Focus Range
  • Not applicable.
  • Eyepieces
  • Not applicable.
  • Eyepiece Tube
  • Not applicable.
  • Illumination
  • Not applicable.
  • Coarse Adjustment Range
  • Not applicable.
  • Fine Adjustment Range
  • Not applicable.
  • Working Stage
  • High-precision X-Y sample tray with multiple vial positions.
  • Still Image Capture Resolution
  • Not applicable.
  • Video Capture Resolution
  • Not applicable.
  • Image Format
  • Not applicable.
  • Interpupillary Distance
  • Not applicable.
  • Objective Achromatic
  • Not applicable.
  • Condenser
  • Not applicable.
  • Light Source
  • Not applicable.
  • Sampling Volume Range
  • 1 L to 10 mL.
  • Protection Class
  • IP21.
  • Weight
  • Approx. 18 kg.
  • Control Software
  • User-friendly touch screen and PC control interface.
  • Maximum Sample Throughput
  • Up to 60 samples/hour.
  • Operating Voltage
  • 220V AC/50Hz.
  • Operating Temperature Range
  • 10C to 40C.
  • Compatible Analysis Methods
  • HPLC, GC, ICP, and other liquid-based analytical instruments.
  • Material of Construction
  • Corrosion-resistant stainless steel and PTFE.
  • Sample Capacity
  • Up to 120 positions for standard 2 mL vials.
 
 

Automated Liquid Autosampler About

Automated Liquid Autosampler offered by us is specifically designed to be used for chromatography techniques. It is known to eliminate chances of volumetric error hence assures precise volume dispensing. This sampler is completely automatic in nature and operates with help of microprocessor-based system. It is equipped with soft keypad for navigating through different parameters. Automated Liquid Autosampler delivers fast, reliable, & precise injections for GC-MS systems thus results in accurate determinations.

Features:

  • Simultaneous injection of multiple reagents
  • Has modular & advanced design
  • Improves high molecular weight chromatographic results


Flexible Sample Capacity and Versatility

Accommodating up to 120 standard 2 mL vials, this autosampler streamlines workflows for laboratories handling diverse sample loads. Its wide sampling range from 1 L to 10 mL enables flexible application across HPLC, GC, ICP, and various liquid-based analyses. Combined with programmable sequences and cleaning cycles, it ensures consistent throughput and minimal downtime.


Precision Engineering and User-Friendly Control

Engineered with corrosion-resistant stainless steel and PTFE, the system withstands harsh chemicals and frequent use. Equipped with a high-resolution adjustable drawtube, accurate to 0.1 L, integrated sensors, and an X-Y position sample tray, it enables precise, repeatable sample extraction. Easy-to-navigate touchscreen and PC interfaces simplify operation and customization.


Robust Connectivity and Reliable Safety Features

Seamless integration into laboratory settings is enabled through USB, RS232, and Ethernet interfaces. Automated leak detection, error alarms, and the IP21 protection class enhance equipment safety and sample integrity, supporting consistent, error-minimized operation across extended analytical runs.

FAQs of Automated Liquid Autosampler:


Q: How does the autosampler ensure precise and repeatable sample introduction?

A: The autosampler uses a high-resolution adjustable drawtube mechanism with 0.1 L volumetric resolution, supported by integrated liquid level and presence sensors. This combination guarantees accurate and consistent sampling for every analysis.

Q: What types of analytical instruments can the autosampler be used with?

A: It is compatible with a range of liquid-based analytical instruments, including HPLC, GC, ICP, and similar systems, extending its versatility in laboratory environments.

Q: When should regular maintenance be performed on the autosampler?

A: Routine maintenance, such as cleaning cycles and checking for wear on sample probes or tubing, should be carried out according to laboratory protocols or after intensive use to sustain optimal performance and reduce downtime.

Q: Where can this autosampler be purchased in India?

A: The Automated Liquid Autosampler is available through authorized distributors and suppliers across India. Please contact your local scientific equipment provider for availability and support.

Q: What is the process for changing sample vials and adjusting sampling volumes?

A: The X-Y sample tray with multiple vial positions allows effortless placement and replacement of up to 120 standard 2 mL vials. Sampling volumes are set via the user-friendly touchscreen or PC software, accommodating volumes from 1 L up to 10 mL.

Q: How does the autosampler benefit laboratory operations?

A: This autosampler streamlines analytical workflows by allowing unattended, fully automated sampling, increasing productivity, reducing manual error, and ensuring reproducible results across a high volume of samples.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Laboratory Equipment Category

CFA Analyzer

CFA Analyzer

Price Range 6000000.00 - 8000000.00 INR

Interface : USB 2.0 & HDMI

Theory : Other, Used for quantitative chemical analysis in laboratories

Resolution : 19201080 pixels

Dimensions : 380180350 mm

Flame Photometer

Flame Photometer

Price Range 390000.00 - 500000.00 INR

Interface : Digital display with simple keypad controls

Theory : Other, Flame Photometry is an analytical technique used for the determination of concentration of certain metal ions, based on their emission spectrum in flame.

Resolution : Up to 0.1 ppm or better depending on element

Dimensions : Approx. 350 x 250 x 300 mm

Ion Chromatography

Ion Chromatography

Price Range 20000.00 - 50000.00 USD ($)

Minimum Order Quantity : 1 Number

Interface : RS232, USB, LAN, with options for data export.

Theory : Other, Ion Chromatography is a process used for separating ions and polar molecules based on their charge properties. It is widely used for water analysis, pharmaceutical, chemical, and food industries.

Resolution : Typically 0.001 mg/L (1 ppb) depending on detector and method applied.

Dimensions : Approx. 450mm x 360mm x 500mm (WxDxH)

Headspace Autosampler for GC

Headspace Autosampler for GC

Price Range 1500000.00 - 2000000.00 INR

Interface : RS232, USB, or LAN for GC communication and data management.

Theory : Other, Headspace sampling is a technique for analyzing volatile compounds in solid or liquid samples by sampling the gas phase above the sample in a sealed vial.

Resolution : Automatic sample injection with high repeatability, ensuring minimal carryover; actual GC detection depends on connected GC system.

Dimensions : Approx. 51 x 58 x 43 cm (model dependent).